Microbial Contamination Risk Levels and Beyond-Use Dating
According to USP <797>, CSPs are assigned primarily according to the potential for microbial contamination during compounding.Potential sources of contamination include, but are not limited to, solid and liquid matter from compounding personnel and objects!non-sterile components employed and incorporated before terminal sterilization!and inappropriate conditions within the restricted compounding environment.
Beyond-Use Date is the date and time after which a CSP shall not be stored or transported.It is determined from the date or time the preparation is compounded.This is also known asDiscard after,Use beforeorAdminister by.
Risk Level | Ingredient : CSP Ratio | Beyond-Use Date | ||
Controlled RT | Refrigerator | Freezer | ||
Low | 1:1 |
48 hours | 14 days | 45 days |
Medium | One : Many or Many : One |
30 hours | 9 days | |
High | Any ingredient-CSP relationship using nonsterile ingredients and/or devices that requires terminal sterilization |
24 hours | 3 days |
The proposed USP <797> revisions collapsed CSP microbial risk categories from three to two and changed terminology.No sterile compounding is inherently "low risk" and preparation of all CSPs must be done carefully.Categories were renamed neutrally and are distinguished primarily by the conditions under which they are made.
Risk Level | Description | Beyond-Use Date | ||
Controlled RT | Refrigerator | |||
Category 1 | PEC placement, Sterility Testing and Endotoxin Testing are not required |
≤12 hours |
≤24 hours | |
Category 2 | PEC is placed in ISO classified air, Sterility testing is based on assigned BUD, Endotoxin testing is not required if with sterile components |
≥12 hours | ≥24 hours |
CSP - Compounded Sterile Preparation!PEC - Primary Engineering Control!RT - Room Temperature
All personnel handling CSPs should be well aware of thebest practicesandprevailing regulation.
It is now time to address USP <797>!
References
1.USP <797> Pharmaceutical Compounding - Sterile Preparations
2.USP <797> Proposed Revision (September 2015)
Esco isolators offerimproved sterility assurancefor the product and aneffective protectionof the healthcare personnel against risks caused by hazardous substances.
For more information contact us at:
Tel: +65 6542 0833