Improving Lives Through Science
›Resources› Esco Hood Selection Guide
Application | Classification and Feature | Protection Against | Model | Image | Remarks | |||||
AAllergen |
BBiohazard |
CChemical Vapor |
DHazardous Drugs |
EEnvironmental |
||||||
AAnimal Handling Can accomodatetrace amountof non-corrosive, non-flammable chemicals with exhaust collar, heating isNOTallowed |
1 | Single-Sided Animal Procedure, Class II A2 Biosafety | ✓ |
✓ |
Add Exhaust Collar | Add Exhaust Collar | ✓ |
VA2 G4 | If using Isoflurane gas, add exhaust collar and gas scavenger unit.Use SLC stand to move under 80" doors.Necropsy variant with sink is available. | |
2 | Double-Sided Animal Transfer | ✓ |
✓ |
VDA | Comes with auto-lift to slide under 80" doors at min height.Quietest dual-sides animal cabinet in the market.ELISA- tested allergen containment. | |||||
3 | Bedding Disposal | ✓ |
✓ |
VBD | Comes with removable 40 gal waste disposal bin and auto-lift to slide under 80" doors at min height.ELISA-tested allergen containment. | |||||
BBiological Samples Handling Can accomodatetrace amountof non-corrosive, non-flammable chemicals with exhaust collar, heating isNOTallowed |
1 | Compact-sized, Class II A2 | ✓ |
Add Exhaust Collar | Add Exhaust Collar | ✓ |
AC2 NS G4 | Energy and space efficient.Lowest BSC in market at 55" height.Add exhaust collar when working with naturally evaporating chemicals. | ||
2 | Full-sized, Class II A2 | ✓ |
Add Exhaust Collar | Add Exhaust Collar | ✓ |
LA2 G4 | Ultimate safety and comfort.Add exhaust collar when working with naturally evaporating chemicals. | |||
3 | Machine enclosure, Class II A2 | ✓ |
Add Exhaust Collar | Add Exhaust Collar | ✓ |
AC2 - Large | 25" usable depth and 36" interior height.Add Exhaust Collar for naturally evaporating chemicals.Use folding window for > 20" larger front opening. | |||
4 | Room-Sized Enclosure, Class II A2 | ✓ |
Add Exhaust Collar | Add Exhaust Collar | ✓ |
BioBooth | 58" D x 34" D x 71" Workzone.Customizable to larger size.Add exhaust collar when working with naturally evaporating chemicals. | |||
5 | Total Exhaust, for Continuous Chemical Injection, Class II B2 | ✓ |
✓ |
✓ |
✓ |
LB2 G4 | Has built-in Exhaust Collar.Also can be used for small amount of non-corrosive flammable chemicals because vapor won't touch internal fan. | |||
CChemical Handling (Ducted) Can accomodatewide-rangeof chemicals that include corrosive and flammable chemicals,heating is allowed |
1 | General Purpose Fume Hood (Ducted) | ✓ |
EFA | Fiberglass-Reinforced Plastic Interior and Epoxy Resin Table.Suitable for a wide range of chemicals at larger amount.Heating allowed.C1D1 option. | |||||
2 | Acid Digestion Fume Hood (Ducted) | ✓ |
EFQ | Polypropylene Plastic Interior and Table.Suitable for a wide range of chemicals at larger amount.Heating is allowed.C1D1 option. | ||||||
3 | Radioisotope Fume Hood (Ducted) | ✓ |
EFI | Stainless Steel 304 or 316 Interior and Table.Suitable for a wide range of chemicals at larger amount.Heating is allowed.C1D1 option. | ||||||
CChemical Handling (Ductless) Forlimited-rangeof chemicals per selected carbon filter, heating isNOTallowed |
1 | Single-Layer Carbon Filter (Limited range of chemicals) | ✓ |
ADC-B | Choose 1 from 8 different types of carbon filter.Suitable only for limited range of chemicals per selected carbon filter. | |||||
2 | Double-Layer Carbon Filter (More range of chemicals) | ✓ |
ADC-C | Choose 2 from 8 different types of carbon filter.Suitable only for limited range of chemicals per selected carbon filter. | ||||||
3 | Single-Layer Carbon + HEPA Filter (Chemical vapor and particulates) | ✓ |
ADC-E | Choose 1 from 8 carbon filters.Limited range of chemicals per selected filter.Suitable for clean room, as HEPA filter captures the carbon particles | ||||||
CCompounding Pharmacy Can accomodatetrace amountof non-corrosive, non-flammable chemicals with exhaust collar, heating isNOTallowed |
1 | Non-Hazardous, Sterile, USP-797 | ✓ |
LHG, LHS | LHG: Glass Sides, to put camera outside the cabinet LHS: Stainless Steel Sides, easier to clean Use STC stand with casters |
|||||
2 | Hazardous, Non-Sterile, USP 800 | ✓ |
PW1,ADC-F | PW1: single HEPA + collar ADC-F: double HEPA |
||||||
3 | Hazardous, Sterile, USP 800 | ✓ |
Add Exhaust Collar | Add Exhaust Collar | ✓ |
AC2 | Add exhaust collar to comply with USP 800.Only for naturally evaporating chemicals.Short 55" height for cleanrooms & mobile labs. | |||
DDNA Amplification Using PCR method |
1 | PCR Cabinet | ✓ |
PCR | Comes with UV lamp, foldable front cover, Blower, and HEPA Filter.Has lower airflow at 60 fpm instead of 90 fpm for Laminar Flow Cabinets. | |||||
EElectronics Plant Tissue Culture Only provides product protection, no operator protection |
1 | Small Electronics, Plant Tissue Culture: use Horizontal Laminar Flow Cabinet | ✓ |
LHG, LHS | LHG: Glass Sides, to put camera outside the cabinet LHS: Stainless Steel Sides, easier to clean, better for ESD Add Ion Bar for ESD application |
|||||
2 | Larger Electronics, Agar Plate Preparation: use Vertical Laminar Flow Cabinet | ✓ |
LVG, LVS | LVG: Glass Sides, more comfortable from claustrophobia LVS: Stainless Steel Sides, easier to clean, better for ESD Add Ion Bar for ESD application |
||||||
3 | Optics Inspection: use Vertical Laminar Flow Cabinet with Black Interior | ✓ |
LVS - Black | Black Interior Walls and Work Surface for Optical Instrument Inspection |